You are here:
- Home
- Batteries
- VRLA Batteries
- Yuasa
- SWL2500E (12V 93.6Ah) Yuasa High Rate VRLA Battery
Product code: SWL2500E
SWL2500E (12V 93.6Ah) Yuasa High Rate VRLA Battery
13,350 EGP
SWL2500E (12V 93.6Ah) Yuasa High Rate VRLA Battery
Model: SWL2500EDownload Product Datasheet
Product successfully added to the Quote List
Description
Characteristics
No Reviews
Description
| Overview | |
| Presentation | SWL2500E (12V 93.6Ah) Yuasa High Rate VRLA Battery Safety Installation: Can be installed and operated in any orientation except permanently inverted. Handles: Batteries must not be suspended by their handles (where fitted). Vent valves: Each cell is fitted with a low pressure release valve to allow gasses to escape and then reseal. Gas release: VRLA batteries release hydrogen gas which can form explosive mixtures in the air. Do not place inside a sealed container. Recycling: YUASA’s VRLA batteries must be recycled at the end of life in accordance with local and national laws and regulations. |
| Lead time | Usually in Stock |
| Specifications | |
| Nominal voltage (V) | 12 |
| 10m rate Constant Power (Typ) to 9.6V at 20°C (W/Block) | 2940 |
| 10m rate Constant Power (Typ) to 1.6V/cell at 20°C (W/Cell) | 490 |
| 10-hr rate Capacity to 1.8V/Cell at 20°C (Ah) | 91.4 |
| 20-hr rate Capacity to 1.75V/Cell at 20°C (Ah) | 93.6 |
| Dimensions | |
| Length (mm) | 305 (±3) |
| Width (mm) | 168 (±2) |
| Height (mm) | 224.5 (±1) |
| Mass (kg) | 33 |
| Terminal Type | |
| Threaded terminal – (M=Male or F=Female) Torque (Nm) | M6 (F) 4.8 |
| Operating Temperature Range | |
| Storage (in fully charged condition) | -20°C to +50°C |
| Charge | -15°C to +50°C |
| Discharge | -20°C to +60°C |
| Storage | |
| Capacity loss per month at 20°C (% approx.) | 3 |
| Case Material | |
| Standard | ABS (UL94:HB) |
| FR version available | UL94:V0 |
| Charge Voltage | |
| Float charge voltage at 20°C (V)/Block | 13.65 (±1%) |
| Float charge voltage at 20°C (V)/Cell | 2.275 (±1%) |
| Float Chg voltage tmp correction factor from std 20°C (mV) | -3 |
| Cyclic (or Boost) charge Voltage at 20°C (V)/Block | 14.5 (±3%) |
| Cyclic (or Boost) charge Voltage at 20°C (V)/Cell | 2.42 (±3%) |
| Cyclic Chg voltage tmp correction factor from std 20°C (mV) | -4 |
| Charge Current | |
| Float charge current limit (A) | No limit |
| Cyclic (or Boost) charge current limit (A) | 22.5 |
| Maximum Discharge Current | |
| 1 second (A) | 1000 |
| 1 minute (A) | 500 |
| Short-Circuit Current & Internal Resistance | |
| Internal resistance – according to EN IEC 60896-21 (mΩ) | 6.5 |
| Short-Circuit current – according to EN IEC 60896-21 (A) | 2258 |
| Impedance | |
| Measured at 1 kHz (mΩ) | 4 |
| Design Life & Approvals | |
| EUROBAT Classification: Long life | 10 to 12 years |
| Yuasa design life at 20°C (yrs) | up to 10 years |